ELECTRICAL ENGINEERING · STEVENS INSTITUTE OF TECHNOLOGY · PRE-MED

I model the body as a circuit.

I'm an electrical engineering student who started in biomedical engineering and is still on the pre-med track. My projects sit where analog circuits, signal processing and physiology meet: EEG filtering, cardiovascular models, neuron simulations and assistive eye tracking.

Raw signal: 10 Hz rhythm + 60 Hz mains + 97 Hz noise After my optimized two-stage RC low-pass Gain at 10 Hz 0.900 · at 100 Hz 0.100

Synthetic input signal passed through my optimized two-stage RC low-pass (R1 2.884 kΩ, R2 19.582 kΩ, C1 1.715 µF, C2 0.229 µF). My work on real EEG recordings is in the first project below.

Research & independent work

02 projects
● In progress

Independent project

EEG Signal Processing & RC Filter Optimization

  • Python
  • LTspice
  • SciPy
  • NumPy
  • MNE-Python
  • Digital signal processing
  • Neural engineering

I designed and optimized a two-stage passive RC low-pass filter to study how electrical circuits affect neural signals in brain-computer interface (BCI) applications.

I modeled the circuit's transfer function, used SciPy to find resistor and capacitor values that meet set frequency-response targets, and checked the design in LTspice. I then applied its frequency response to real human EEG from the PhysioNet EEG Motor Movement/Imagery Dataset.

What I built

  • Circuit design. A two-stage RC low-pass filter in LTspice, with its transfer function derived by hand.
  • Numerical optimization. SciPy's Nelder–Mead algorithm tuned four components to keep at least 90% of amplitude at 10 Hz and pass at most 10% at 100 Hz in the mathematical model.
  • EEG processing. MNE-Python and NumPy for FFT-based filtering and inverse-FFT reconstruction of real recordings.
  • Signal analysis. Original and circuit-filtered EEG compared in the time and frequency domains.
  • Motor imagery (in progress). Finding left-hand and right-hand imagery segments to look at changes in mu (8–13 Hz) and beta (13–30 Hz) activity.

Optimized design

ComponentOptimized value
R12.884 kΩ
R219.582 kΩ
C11.715 µF
C20.229 µF

H(s) = 1 / (R1·R2·C1·C2·s² + (R1·C1 + R1·C2 + R2·C2)·s + 1)

With these values the model's amplitude response is 0.900 at 10 Hz and 0.0998 at 100 Hz, so it meets both targets.

Next

Quantify motor-related EEG activity at the C3 and C4 electrodes, measure how well it survives the circuit filtering, and test whether extracted features can tell left-hand from right-hand imagery.

How does analog filter design change the neural information a brain-computer interface can use?

Vin R1 2.884 kΩ R2 19.582 kΩ C1 1.715 µF C2 0.229 µF Vout
Two-stage passive RC low-pass with the optimized component values.
Design targets on a log-frequency axis: at least 0.90 at 10 Hz, at most 0.10 at 100 Hz. The curve is the response of my optimized circuit from its transfer function (model, not a measurement).

NYU Langone Health · Rusk Rehabilitation · Rizzo Lab

Eye-Tracking Accessibility for Neurological Rehabilitation

  • Biomedical engineering
  • Assistive technology
  • Eye tracking
  • Computational neuroscience
  • Python

I contributed to research on eye tracking as an accessible way to use a computer for people with neurological conditions, including Parkinson's disease, multiple sclerosis and progressive supranuclear palsy. The work focused on gaze-tracking accuracy and on adaptive calibration for atypical eye movements.

Contributions

  • Eye-movement analysis. Python analysis of saccades, fixations and gaze-position error.
  • Signal processing. Methods to separate natural fixation from rapid eye movements so gaze measurements are more reliable.
  • Adaptive calibration. Calibration approaches meant to improve tracking for users with neurological impairments.
  • Quantitative evaluation. Analysis of 144 eye-tracking trials involving supranuclear gaze palsy.

Why it matters

Standard eye trackers can struggle when a user's eyes move atypically, which can lock them out of gaze-controlled interfaces. Better calibration could help assistive communication, human-computer interaction and rehabilitation.

Can computational eye-movement analysis make gaze interfaces usable for people with movement disorders?

BeforeAfter
Mean gaze-position error across 144 trials, in pixels: about a 5.3% reduction. Preliminary analysis, values rounded. These results do not establish clinical effectiveness or generalizability.

Coursework projects

Stevens Institute of Technology · 04 projects

Select a project to open the details.

Academic engineering project

Cardiovascular Hemodynamics Modeling

  • MATLAB
  • Simulink
  • Mathematical modeling
  • Numerical analysis
  • Built a lumped-parameter cardiovascular model with a three-element Windkessel, using vascular resistance, arterial compliance and peripheral resistance.
  • Simulated arterial pressure under baseline and modified parameters, and wrote MATLAB functions for mean arterial, systolic, diastolic and pulse pressure.
  • Compared waveforms to see how parameter changes tied to hypertension shift the results.
MeasurementBaselineModified
Mean arterial pressure85.21103.17
Systolic pressure110.60132.20
Diastolic pressure69.0282.12
Pulse pressure41.5850.08

Circuit-style modeling can represent a physiological system, and small changes in resistance and compliance visibly change simulated pressure. Values in mmHg; bars on a 0–140 scale.

BME 206 · Individual project

Neuron Modeling & Prosthetic Sensory Feedback

  • MATLAB
  • ode45
  • Differential equations
  • FitzHugh–Nagumo
  • Computational neuroscience
  • Simulated action potentials with the FitzHugh–Nagumo model in MATLAB, solved with ode45.
  • Applied constant and time-dependent stimulation, and ran a parameter study on how the recovery parameter ε affects spike duration and excitability.
  • Fed sample pressure-sensor data from a prosthetic hand into the model to see how different grip forces produce different firing patterns.
ConditionPeak pressureNeural spikes
Light grip251
Firm grip706

The model turned two different sensor readings into two different firing responses, a first step toward sensory encoding for neuroprosthetics.

ENGR 122 · Team project

Autonomous Tour Guide Robot

  • Arduino / C++
  • MQTT
  • PWM
  • Ultrasonic sensors
  • I2C
  • OLED
  • SolidWorks
  • 3D printing

A robot that follows a set campus route, avoids obstacles and reports its status live. Sensing, control, communication and actuation all run on one embedded system.

  • Helped build the navigation system for visiting several target locations in sequence.
  • Used ultrasonic sensing to detect nearby obstacles and trigger avoidance.
  • Wrote embedded control logic that turns sensor input into PWM motor commands.
  • Received real-time position data over MQTT to support navigation.
  • Showed live robot variables on an OLED over I2C for debugging.
  • Took part in iterative testing and calibration to improve navigation and actuator response.

How can a robot combine sensing, communication and control to reach set targets safely in a changing environment?

ENGR 111 · Team project

Automated Plant Watering & Environmental Monitoring

  • Arduino
  • C/C++
  • MQTT
  • PWM
  • ADC
  • IoT

An automated irrigation system that reads soil moisture, air temperature, humidity and light, and runs a water pump when conditions call for it.

  • Added threshold-based control logic that switches the pump on when watering conditions are met.
  • Used GPIO, analog-to-digital conversion and PWM to connect sensors and actuators.
  • Wrote Arduino code that samples every 10 minutes and sends readings to an MQTT server.
  • Assembled the electronics, pump, sensors and reservoir into a working prototype.

Embedded programming, sensing, automated control and wireless data in one small Internet of Things system.

Background

how the projects fit together

I'm a sophomore at Stevens. I spent my first year and a half in biomedical engineering, then switched to electrical engineering. Much of my work already leaned that way: filters, sensors, and models of how a system responds to a signal.

I'm also on the pre-med track and have taken a large share of the biology and chemistry sequence, including labs. That keeps me close to the physiology my engineering work is meant to serve, whether it's an EEG recording, a pressure waveform or a gaze trace from a patient.

My long-term goal is an MD/PhD focused on neural engineering: brain-computer interfaces, neuroprosthetics and assistive technology for people with neurological conditions. My electrical engineering coursework starts next year, and the EEG and eye-tracking projects above are where I'm building toward that.

  1. Year 1 to 2 Biomedical engineering

    Physiological modeling, neuron simulation, first embedded projects. Ongoing pre-med chemistry and biology.

  2. Now Electrical engineering

    Switched majors. Building the EEG filter project and research in eye-tracking accessibility.

Seeking research and internship opportunities in neural engineering.

I'm interested in research programs and internships involving brain-computer interfaces, biosignal processing, assistive technology and biomedical devices. Thank you for taking the time to look through my work.